Where a BAPC machine exposes its processor's energy counters (Linux RAPL, /sys/class/powercap/intel-rapl*/energy_uj), the Energira agent reads them: once with the machine idle and once with one core busy, and Energira uses watts per vCPU at full load = (busy − idle) + idle ÷ vCPUs. Those figures are labelled measured.
Today BAPC's only benchmark machine, the Hetzner CPX22 in Helsinki (AMD EPYC Genoa under KVM), does not expose RAPL: on 23 Nov 2026 its /sys/class/powercap was empty and it has no hardware sensors, as is normal for a virtual machine. The agent records this check every hour once it is installed. So its figures are modelled, like every other provider's.
Energy of cloud compute (modelled)
Cloud Carbon Footprint's method: watts per vCPU = idle watts + utilisation × (full-load watts − idle watts), plus 0.392 W per GB of memory (range 0.314 to 0.470). Comparisons use 50% utilisation, CCF's default. Facility energy = IT energy × PUE.
| Hardware | Idle W per vCPU | Full-load W per vCPU | Where the range comes from |
|---|---|---|---|
| AMD EPYC 4th Gen (Genoa) | 0.7391 | 2.2822 | CCF EPYC 4th Gen coefficients (from SPECpower whole-server results); BAPC sets ±20% because the coefficient comes from other Genoa systems, not this host. |
| Azure fleet average (CCF) | 0.78 | 3.76 | Central: CCF Azure average. Range: CCF EPYC Milan (low) to Intel Sapphire Rapids (high), because Troapō prices many Azure families. |
| Unpublished hardware (mean of CCF AWS, GCP and Azure averages) | 0.7433 | 3.84 | The provider does not publish its processors; central is the mean of CCF's three cloud averages, range is CCF EPYC Milan to Sapphire Rapids. |
Energy of an AI request (modelled, EcoLogits method)
GPU energy per output token per GPU = 0.00000117 × e-0.0112 × 64 × active parameters (billions) + 0.0000405 Wh (batch 64). GPUs = memory (1.2 × parameters × 2 bytes) ÷ 80 GB, rounded up to a power of two. Server energy = time × 1.2 kW × GPUs ÷ 8 ÷ 64, where time is the shorter of the modelled generation time and the call's measured latency. Facility energy × PUE. Energira sets a range of ×0.5 to ×2 on the GPU fit: Hugging Face's AI Energy Score measured Meta-Llama-3.1-8B at 17.38 Wh per 1,000 queries on an H100 at batch 1, against about 11 Wh from this formula at 250 output tokens.
| Model | Parameters |
|---|---|
| meta/llama-3.1-8b-instruct-fp8-fast | dense 8B |
| meta/llama-3.3-70b-instruct-fp8-fast | dense 70B |
| mistral/mistral-small-3.1-24b-instruct | dense 24B |
| ibm/granite-4.0-h-micro | dense 3B (hybrid) |
| openai/gpt-oss-20b | mixture of experts, 21B total, 3.6B active |
| google/gemma-4-26b-a4b-it | mixture of experts, 26B total, about 4B active (a4b) |
| Closed models (Claude, GPT, Gemini) | parameter count not published: wide range (EcoLogits treats closed mixture-of-experts models as 10-30% active); estimate only, not rated |
Carbon by region
Location-based (GHG Protocol Scope 2 Guidance: "the average emissions intensity of grids on which energy consumption occurs"): facility kWh × the grid's annual average. US grids use EPA eGRID2023 subregions (direct emissions); other countries use Ember's 2025 lifecycle figures. Each row says which.
| Grid | g CO2e per kWh | Basis and range | Source |
|---|---|---|---|
| us-srvc | 270.489 gCO2e/kWh | direct (combustion) emissions, eGRID2023 annual subregion average | source |
| us-rfce | 271.779 gCO2e/kWh | direct (combustion) emissions, eGRID2023 annual subregion average | source |
| us-camx | 195.037 gCO2e/kWh | direct (combustion) emissions, eGRID2023 annual subregion average | source |
| us-avg | 349.667 gCO2e/kWh | direct (combustion) emissions, eGRID2023 annual subregion average | source |
| NL | 253.560 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| DE | 329.650 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| GB | 217.410 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| FI | 57.470 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| SG | 497.090 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| JP | 477.260 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| US | 384.400 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
| EU | 209.900 gCO2e/kWh | lifecycle emissions, Ember 2025 national annual average | source |
Market-based ("electricity that companies have purposefully chosen"): location-based × (1 − share the provider says it covers with renewable certificates or contracts). BAPC cannot verify the certificates, so the high end of every market-based figure assumes no cover. Where a provider publishes no claim, the market-based figure equals the grid average: the GHG Protocol would use a residual mix, but the AIB European residual mixes are "All rights reserved", so BAPC does not redistribute them.
- Microsoft Azure: Microsoft matched 100% of annual global electricity with renewable energy in FY25 (annual matching, not hourly).
- Hetzner: Hetzner buys 100% renewable Guarantees of Origin for its German and Finnish data centres.
- Vultr: No renewable claim published for this provider and site: grid average used (residual mix not licensed for redistribution).
- Akamai (Linode): Akamai reports a 52% renewable energy share globally (2025); not broken down by site.
- Cloudflare Workers AI: Cloudflare reports Scope 2 market-based 0 tCO2e for 2024 (renewable certificates matching its energy use).
Overhead and water
| Factor | Value | Basis and range | Source |
|---|---|---|---|
| Microsoft Azure PUE (Europe) | 1.160 ratio | provider-published | source |
| Microsoft Azure on-site water, WUE (Europe) | 0.030 L/kWh | provider-published | source |
| Hetzner PUE (Europe) | 1.130 ratio | provider-published | source |
| Hetzner on-site water, WUE (Europe) | 0.360 L/kWh | industry average (provider publishes none) (includes a BAPC assumption) | source |
| Vultr PUE (Europe) | 1.380 ratio | colocation proxy (includes a BAPC assumption) | source |
| Vultr on-site water, WUE (Europe) | 0.590 L/kWh | colocation proxy (includes a BAPC assumption) | source |
| Akamai (Linode) PUE (Europe) | 1.380 ratio | colocation proxy (includes a BAPC assumption) | source |
| Akamai (Linode) on-site water, WUE (Europe) | 0.590 L/kWh | colocation proxy (includes a BAPC assumption) | source |
| Microsoft Azure PUE (Asia Pacific) | 1.280 ratio | provider-published | source |
| Microsoft Azure WUE (Americas) | 0.340 L/kWh | provider-published | source |
| Microsoft Azure WUE (Asia Pacific) | 0.250 L/kWh | provider-published | source |
| Off-site water, us-srvc | 2.385 L/kWh | grid-average water consumption for generation | source |
| Off-site water, us-rfce | 2.309 L/kWh | grid-average water consumption for generation | source |
| Off-site water, us-camx | 5.185 L/kWh | grid-average water consumption for generation | source |
| Off-site water, US | 3.142 L/kWh | grid-average water consumption for generation | source |
| Off-site water, NL | 3.444 L/kWh | grid-average water consumption for generation | source |
| Off-site water, DE | 1.930 L/kWh | grid-average water consumption for generation | source |
| Off-site water, GB | 2.347 L/kWh | grid-average water consumption for generation | source |
| Off-site water, FI | 4.542 L/kWh | grid-average water consumption for generation | source |
| Off-site water, JP | 2.309 L/kWh | grid-average water consumption for generation | source |
| Off-site water, SG | 4.807 L/kWh | grid-average water consumption for generation (includes a BAPC assumption) | source |
| Off-site water, EU | 4.807 L/kWh | grid-average water consumption for generation (includes a BAPC assumption) | source |
Water = IT kWh × WUE (cooling at the site) + facility kWh × the water consumed generating that grid's electricity.
Embodied hardware emissions: estimates
The manufacturing share of a server, spread over its life (Cloud Carbon Footprint and the Green Software Foundation SCI method): host embodied total × (hours used ÷ lifespan hours) × (vCPUs used ÷ host vCPUs). Host total 1611 kg CO2e (CCF's figure for a 96-vCPU general-purpose host; low 1000, high +50%), lifespan 4 years (low end 5, high end 3). AI: EcoLogits' 5,700 kg per 8-GPU server without GPUs plus 273 kg per H100, over 3 years, shared across the batch. These are estimates, always shown and exported separately from operational emissions.
Uncertainty
Every input has a low, central and high value (above). Every output is propagated through the same formulas: low uses every low input, high every high input. Because every formula only adds and multiplies positive numbers, this gives bounds that contain the true value whenever the inputs' ranges do. It is not a statistical confidence interval (the GHG Protocol's "parameter uncertainty", propagated). Ranges are shown on every page and in every export.
Ratings A to F
Cloud: location-based g CO2e + embodied g CO2e for one vCPU-hour at 50% utilisation. A: up to 0.5 g · B: up to 1 g · C: up to 1.5 g · D: up to 2 g · E: up to 3 g · F: above 3 g.
AI models: location-based g CO2e + embodied g CO2e per 1,000 output tokens. A: up to 0.05 g · B: up to 0.1 g · C: up to 0.25 g · D: up to 0.5 g · E: up to 1 g · F: above 1 g. Closed models are not rated.
The grade is that of the central figure; the grades of the low and high figures are shown when they differ. Bands are fixed, not curved, so a grade means the same thing every month. Formula version energira-rating-1.0.0.
Exports
- GHG Protocol-compatible CSV and JSON: Scope 3 Category 1 (purchased services) view; cloud and AI services are put in Category 1 by common practice (the GHG Protocol text does not name cloud). Location- and market-based totals side by side with low, central and high, the emission factor, its basis, year, source, URL and licence on every row; embodied as a separate estimate; water; the GHG Protocol data-quality indicators (technological, temporal and geographical representativeness, completeness, reliability).
- Climatiq: a private emission factors CSV using exactly the columns in Climatiq's guide (name, activity_id, region, year, activity_unit, calculation_method, source_lca_activity, co2e_total, sector, category, source, source_link, uncertainty, scopes, description, unit), and estimate request bodies (emission_factor with activity_id, data_version, region, year; parameters energy and energy_unit) that reference those factors. Climatiq's cloud computing endpoints were withdrawn in 2026, so energy-based estimates are used. Private factors are a Climatiq preview feature you enable with Climatiq.
- Watershed, Persefoni and Sweep do not publish their import templates (they map uploaded columns on import). Energira provides a neutral activity-data CSV (dates, supplier, description, quantity, unit, emission factor and source, kg CO2e with range, accounting method, scope, category) named to map in one step. No vendor-specific format is claimed.
Grid data sources
| Source | State | Needs | Price | Terms |
|---|---|---|---|---|
| Energy-Charts (Fraunhofer ISE) | live | — | free | CC BY 4.0 unless stated otherwise; /co2eq is undocumented, so used as a cross-check only and not sold |
| Ember API | waiting for key | a free Ember API key (register at ember-energy.org/data/api), set as EMBER_API_KEY | free (no paid plan listed) | CC BY 4.0, personal or commercial use, cite Ember |
| US EIA Open Data API v2 | waiting for key | a free EIA API key (register at eia.gov/opendata), set as EIA_API_KEY | free | US Government public domain, cite EIA |
| Electricity Maps API | blocked | a commercial Electricity Maps licence, key set as ELECTRICITYMAPS_KEY | from EUR 2,500 per year per country (Sustainability plan) | free tier is non-commercial; product use needs a paid licence |
| WattTime API (marginal emissions) | blocked | a paid WattTime Analyst or Pro plan (MOER data), login set as WATTTIME_USER and WATTTIME_PASSWORD | price on request (not listed) | free data is a 0-100 index; research terms forbid commercial use |
| ENTSO-E Transparency Platform | blocked | a token (free, requested by email to transparency@entsoe.eu) and written confirmation that commercial re-use is allowed for generation-per-type data | free | open-data licence covers a listed subset only; commercial re-use not confirmed |
Limits
- Only BAPC's own machine is benchmarked (one Hetzner server); other providers are compared per vCPU-hour from their published hardware, prices and sites, not from runs on their servers.
- Storage and network transfer are not yet included.
- Providers do not publish per-region PUE or WUE (Microsoft publishes by continent; Hetzner a fleet range); where nothing is published a colocation figure is used and marked.
- Grid factors are annual averages; the hour of use is not taken into account.
- Ember 2025 values are read from Our World in Data's copy of Ember's data until the Ember API key is set.
Sources
- Cloud Carbon Footprint methodology and ccf-coefficients (SPECpower-based watts per vCPU, memory 0.392 W/GB, embodied method). Apache-2.0 (github.com/cloud-carbon-footprint). Used for: CPU and memory power model, embodied emissions method.
- ccf-coefficients: coefficients-aws-use.csv and coefficients-aws-embodied.csv. Apache-2.0. Used for: per-microarchitecture watts per vCPU (AMD EPYC Genoa, Milan, Intel Sapphire Rapids); embodied kgCO2e per host.
- SPECpower_ssj2008 result: Dell PowerEdge R7615, 1x AMD EPYC 9654P (published 18 Sep 2023). SPEC fair use (cited with source and date; SPEC and SPECpower are trademarks of SPEC). Used for: cross-check of the Genoa per-thread power (about 0.40 W idle, 1.81 W at 100% per thread, derived, not a SPEC metric).
- EcoLogits LLM inference methodology (GenAI Impact). methodology CC BY-SA 4.0; code MPL-2.0 (Energira re-implements the published formulas; it does not copy the code). Used for: energy per AI request from output length and active parameters; GPU count; server overhead; embodied per request.
- Hugging Face AI Energy Score leaderboard (text generation, H100, batch 1). code MIT, Space Apache-2.0. Used for: cross-check of the AI model: Meta-Llama-3.1-8B measured 17.38 Wh per 1,000 queries (Feb 2025).
- Ember yearly electricity data, lifecycle carbon intensity 2025 (via Our World in Data mirror; confirmed against the Ember API once its key is set). CC BY 4.0 (Ember: "for any purpose, personal or commercial"). Used for: location-based grid carbon intensity outside the US.
- US EPA eGRID2023 (Rev 2, 12 Jun 2025) total output CO2e emission rates by subregion. US Government public domain (EPA Data License). Used for: location-based grid carbon intensity in the US.
- Microsoft datacenter efficiency: PUE and WUE by geography, FY24 and FY25. published facts, cited. Used for: Azure PUE and on-site WUE.
- Microsoft 2026 sustainability report: "In FY25, we matched 100% of our annual global electricity consumption with renewable energy". published claim, cited. Used for: Azure market-based figure.
- Hetzner: average PUE 1.13 (2025, Germany and Finland, range 1.10 to 1.16 per location); 100% renewable energy certificates (Guarantees of Origin) for German and Finnish data centres. published facts, cited. Used for: Hetzner PUE and market-based figure.
- Akamai 2025 Impact Report: renewable energy share 52% globally. published claim, cited. Used for: Akamai market-based figure.
- Cloudflare 2024 Emissions Inventory: Scope 2 market-based 0 tCO2e (renewable certificates via 3Degrees). published facts, cited. Used for: Cloudflare Workers AI market-based figure.
- Digital Realty 2025 Impact Report: global PUE 1.38, WUE 0.59 L/kWh. published facts, cited. Used for: colocation proxy PUE and WUE where a provider publishes none (Vultr, Akamai, Cloudflare).
- LBNL 2024 United States Data Center Energy Usage Report (LBNL-2001637): on-site WUE about 0.36 L/kWh (2023); indirect water 4.52 L/kWh. US Government work (public). Used for: on-site water where no provider figure exists; upper end of US off-site water.
- WRI Guidance for Calculating Water Use Embedded in Purchased Electricity (2020), grid-average consumption factors. CC BY 4.0. Used for: off-site water consumed generating the electricity.
- GHG Protocol Scope 2 Guidance (location-based and market-based methods). cited. Used for: location- and market-based definitions in exports.
- GHG Protocol Scope 3 Standard and Category 1 technical guidance (data quality indicators, uncertainty types). cited. Used for: Scope 3 Category 1 view and data-quality columns in exports.
- IPCC AR5 WGIII Annex III, lifecycle emissions of electricity supply technologies (median gCO2e/kWh). cited. Used for: fuel factors applied to EIA hourly fuel mix (adapter, waiting for key).