BAPC Data Harvest · DH-16 · method

BAPC Energira

Cloud & AI Carbon Efficiency Ratings

Measured or modelled

Where a BAPC machine exposes its processor's energy counters (Linux RAPL, /sys/class/powercap/intel-rapl*/energy_uj), the Energira agent reads them: once with the machine idle and once with one core busy, and Energira uses watts per vCPU at full load = (busy − idle) + idle ÷ vCPUs. Those figures are labelled measured.

Today BAPC's only benchmark machine, the Hetzner CPX22 in Helsinki (AMD EPYC Genoa under KVM), does not expose RAPL: on 23 Nov 2026 its /sys/class/powercap was empty and it has no hardware sensors, as is normal for a virtual machine. The agent records this check every hour once it is installed. So its figures are modelled, like every other provider's.

Energy of cloud compute (modelled)

Cloud Carbon Footprint's method: watts per vCPU = idle watts + utilisation × (full-load watts − idle watts), plus 0.392 W per GB of memory (range 0.314 to 0.470). Comparisons use 50% utilisation, CCF's default. Facility energy = IT energy × PUE.

HardwareIdle W per vCPUFull-load W per vCPUWhere the range comes from
AMD EPYC 4th Gen (Genoa)0.7391 (0.591 to 0.887)2.2822 (1.826 to 2.739)CCF EPYC 4th Gen coefficients (from SPECpower whole-server results); BAPC sets ±20% because the coefficient comes from other Genoa systems, not this host.
Azure fleet average (CCF)0.78 (0.456 to 1.036)3.76 (1.957 to 4.160)Central: CCF Azure average. Range: CCF EPYC Milan (low) to Intel Sapphire Rapids (high), because Troapō prices many Azure families.
Unpublished hardware (mean of CCF AWS, GCP and Azure averages)0.7433 (0.456 to 1.036)3.84 (1.957 to 4.160)The provider does not publish its processors; central is the mean of CCF's three cloud averages, range is CCF EPYC Milan to Sapphire Rapids.

Cross-check: SPECpower_ssj2008, Dell PowerEdge R7615 with one AMD EPYC 9654P (published 18 Sep 2023): 77.4 W at active idle and 347 W at 100% for 192 threads, about 0.40 and 1.81 W per thread (derived by BAPC, not SPEC metrics). One Troapō workload unit keeps one core at 100% for its measured time.

Energy of an AI request (modelled, EcoLogits method)

GPU energy per output token per GPU = 0.00000117 × e-0.0112 × 64 × active parameters (billions) + 0.0000405 Wh (batch 64). GPUs = memory (1.2 × parameters × 2 bytes) ÷ 80 GB, rounded up to a power of two. Server energy = time × 1.2 kW × GPUs ÷ 8 ÷ 64, where time is the shorter of the modelled generation time and the call's measured latency. Facility energy × PUE. Energira sets a range of ×0.5 to ×2 on the GPU fit: Hugging Face's AI Energy Score measured Meta-Llama-3.1-8B at 17.38 Wh per 1,000 queries on an H100 at batch 1, against about 11 Wh from this formula at 250 output tokens.

ModelParameters
meta/llama-3.1-8b-instruct-fp8-fastdense 8B
meta/llama-3.3-70b-instruct-fp8-fastdense 70B
mistral/mistral-small-3.1-24b-instructdense 24B
ibm/granite-4.0-h-microdense 3B (hybrid)
openai/gpt-oss-20bmixture of experts, 21B total, 3.6B active
google/gemma-4-26b-a4b-itmixture of experts, 26B total, about 4B active (a4b)
Closed models (Claude, GPT, Gemini)parameter count not published: wide range (EcoLogits treats closed mixture-of-experts models as 10-30% active); estimate only, not rated

Where the request was served is not published by Cloudflare or the model makers, so the grid range is the EU (low), the United States (central) and Singapore (high).

Carbon by region

Location-based (GHG Protocol Scope 2 Guidance: "the average emissions intensity of grids on which energy consumption occurs"): facility kWh × the grid's annual average. US grids use EPA eGRID2023 subregions (direct emissions); other countries use Ember's 2025 lifecycle figures. Each row says which.

Gridg CO2e per kWhBasis and rangeSource
us-srvc270.489 (243.440 to 324.586) gCO2e/kWhdirect (combustion) emissions, eGRID2023 annual subregion average
eGRID2023 SRVC (Virginia/Carolinas) 596.326 lb CO2e/MWh. Low -10% (newer, cleaner years). High +20% to cover upstream (lifecycle) emissions eGRID leaves out.
source
US Government public domain (EPA Data License)
us-rfce271.779 (244.601 to 326.134) gCO2e/kWhdirect (combustion) emissions, eGRID2023 annual subregion average
eGRID2023 RFCE (New Jersey/Pennsylvania east) 599.17 lb CO2e/MWh. Low -10% (newer, cleaner years). High +20% to cover upstream (lifecycle) emissions eGRID leaves out.
source
US Government public domain (EPA Data License)
us-camx195.037 (175.533 to 234.044) gCO2e/kWhdirect (combustion) emissions, eGRID2023 annual subregion average
eGRID2023 CAMX (California) 429.983 lb CO2e/MWh. Low -10% (newer, cleaner years). High +20% to cover upstream (lifecycle) emissions eGRID leaves out.
source
US Government public domain (EPA Data License)
us-avg349.667 (314.700 to 419.600) gCO2e/kWhdirect (combustion) emissions, eGRID2023 annual subregion average
eGRID2023 US average 770.884 lb CO2e/MWh. Low -10% (newer, cleaner years). High +20% to cover upstream (lifecycle) emissions eGRID leaves out.
source
US Government public domain (EPA Data License)
NL253.560 (228.204 to 278.916) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 Netherlands 253.56 (2023: 268.17). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
DE329.650 (296.685 to 362.920) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 Germany 329.65 (2023: 362.92). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
GB217.410 (195.669 to 239.151) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 United Kingdom 217.41 (2023: 235.63). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
FI57.470 (51.723 to 81.210) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 Finland 57.47 (2023: 81.21). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
SG497.090 (447.381 to 546.799) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 Singapore 497.09 (2023: 500.87). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
JP477.260 (429.534 to 524.986) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 Japan 477.26 (2023: 492.45). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
US384.400 (345.960 to 422.840) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 United States 384.4 (2023: 392.89). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")
EU209.900 (188.910 to 235.840) gCO2e/kWhlifecycle emissions, Ember 2025 national annual average
Ember 2025 European Union 209.9 (2023: 235.84). Low -10% (hourly and site variation). High: the 2023 value or +10%, whichever is higher.
source
CC BY 4.0 (Ember: "for any purpose, personal or commercial")

Market-based ("electricity that companies have purposefully chosen"): location-based × (1 − share the provider says it covers with renewable certificates or contracts). BAPC cannot verify the certificates, so the high end of every market-based figure assumes no cover. Where a provider publishes no claim, the market-based figure equals the grid average: the GHG Protocol would use a residual mix, but the AIB European residual mixes are "All rights reserved", so BAPC does not redistribute them.

Overhead and water

FactorValueBasis and rangeSource
Microsoft Azure PUE (Europe)1.160 (1.125 to 1.185) ratioprovider-published
Central: Microsoft FY25 Americas/EMEA PUE 1.16. Low: newest designs 1.125, high: fleet 1.185 (both as cited by CCF).
source
published facts, cited
Microsoft Azure on-site water, WUE (Europe)0.030 (0.030 to 0.100) L/kWhprovider-published
Microsoft EMEA WUE 0.03 (FY24 and FY25); high 0.10 is a BAPC margin.
source
published facts, cited
Hetzner PUE (Europe)1.130 (1.100 to 1.160) ratioprovider-published
Hetzner 2025 average 1.13, per-location range 1.10 to 1.16 as published.
source
published facts, cited
Hetzner on-site water, WUE (Europe)0.360 (0.000 to 0.590) L/kWhindustry average (provider publishes none) (includes a BAPC assumption)
Hetzner publishes no WUE. Central: LBNL US data-centre average 0.36; low 0 (free air cooling uses almost no water); high Digital Realty 0.59.
source
US Government work (public)
Vultr PUE (Europe)1.380 (1.150 to 1.500) ratiocolocation proxy (includes a BAPC assumption)
Provider publishes no PUE. Central: Digital Realty 2025 global PUE 1.38. Low 1.15 (Sabey Columbia, where Vultr hosts GPUs). High 1.5 is a BAPC assumption for older sites.
source
published facts, cited
Vultr on-site water, WUE (Europe)0.590 (0.360 to 0.950) L/kWhcolocation proxy (includes a BAPC assumption)
Provider publishes no WUE. Central: Digital Realty 2025 WUE 0.59. Low: LBNL US data-centre average 0.36. High: Equinix 2024 WUE 0.95 (from Equinix report summaries).
source
published facts, cited
Akamai (Linode) PUE (Europe)1.380 (1.150 to 1.500) ratiocolocation proxy (includes a BAPC assumption)
Provider publishes no PUE. Central: Digital Realty 2025 global PUE 1.38. Low 1.15 (Sabey Columbia, where Vultr hosts GPUs). High 1.5 is a BAPC assumption for older sites.
source
published facts, cited
Akamai (Linode) on-site water, WUE (Europe)0.590 (0.360 to 0.950) L/kWhcolocation proxy (includes a BAPC assumption)
Provider publishes no WUE. Central: Digital Realty 2025 WUE 0.59. Low: LBNL US data-centre average 0.36. High: Equinix 2024 WUE 0.95 (from Equinix report summaries).
source
published facts, cited
Microsoft Azure PUE (Asia Pacific)1.280 (1.250 to 1.340) ratioprovider-published
Microsoft Asia Pacific PUE FY24 1.25, FY25 1.28; high adds 5%.
source
published facts, cited
Microsoft Azure WUE (Americas)0.340 (0.340 to 0.460) L/kWhprovider-published
Microsoft Americas WUE FY25 0.34 (FY24 0.38); high = FY24 + 20%.
source
published facts, cited
Microsoft Azure WUE (Asia Pacific)0.250 (0.030 to 0.300) L/kWhprovider-published
Microsoft Asia Pacific WUE FY25 0.25 (FY24 published as 0.03); high = FY25 + 20%.
source
published facts, cited
Off-site water, us-srvc2.385 (1.669 to 3.100) L/kWhgrid-average water consumption for generation
WRI 2020 eGRID SRVC 0.63 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, us-rfce2.309 (1.616 to 3.002) L/kWhgrid-average water consumption for generation
WRI 2020 eGRID RFCE 0.61 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, us-camx5.185 (3.630 to 6.741) L/kWhgrid-average water consumption for generation
WRI 2020 eGRID CAMX 1.37 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, US3.142 (2.199 to 4.084) L/kWhgrid-average water consumption for generation
WRI 2020 United States 0.83 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, NL3.444 (2.411 to 4.478) L/kWhgrid-average water consumption for generation
WRI 2020 Netherlands 0.91 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, DE1.930 (1.351 to 2.509) L/kWhgrid-average water consumption for generation
WRI 2020 Germany 0.51 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, GB2.347 (1.643 to 3.051) L/kWhgrid-average water consumption for generation
WRI 2020 Great Britain 0.62 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, FI4.542 (3.179 to 5.905) L/kWhgrid-average water consumption for generation
WRI 2020 Finland 1.2 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, JP2.309 (1.616 to 3.002) L/kWhgrid-average water consumption for generation
WRI 2020 Japan 0.61 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, SG4.807 (3.365 to 6.249) L/kWhgrid-average water consumption for generation (includes a BAPC assumption)
WRI 2020 global weighted average (Singapore not covered) 1.27 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0
Off-site water, EU4.807 (3.365 to 6.249) L/kWhgrid-average water consumption for generation (includes a BAPC assumption)
WRI 2020 global weighted average (EU not given as one figure) 1.27 gal/kWh (thinkstep 2018 data). ±30% BAPC range for the data's age.
source
CC BY 4.0

Water = IT kWh × WUE (cooling at the site) + facility kWh × the water consumed generating that grid's electricity.

Embodied hardware emissions: estimates

The manufacturing share of a server, spread over its life (Cloud Carbon Footprint and the Green Software Foundation SCI method): host embodied total × (hours used ÷ lifespan hours) × (vCPUs used ÷ host vCPUs). Host total 1611 kg CO2e (CCF's figure for a 96-vCPU general-purpose host; low 1000, high +50%), lifespan 4 years (low end 5, high end 3). AI: EcoLogits' 5,700 kg per 8-GPU server without GPUs plus 273 kg per H100, over 3 years, shared across the batch. These are estimates, always shown and exported separately from operational emissions.

Uncertainty

Every input has a low, central and high value (above). Every output is propagated through the same formulas: low uses every low input, high every high input. Because every formula only adds and multiplies positive numbers, this gives bounds that contain the true value whenever the inputs' ranges do. It is not a statistical confidence interval (the GHG Protocol's "parameter uncertainty", propagated). Ranges are shown on every page and in every export.

Ratings A to F

Cloud: location-based g CO2e + embodied g CO2e for one vCPU-hour at 50% utilisation. A: up to 0.5 g · B: up to 1 g · C: up to 1.5 g · D: up to 2 g · E: up to 3 g · F: above 3 g.

AI models: location-based g CO2e + embodied g CO2e per 1,000 output tokens. A: up to 0.05 g · B: up to 0.1 g · C: up to 0.25 g · D: up to 0.5 g · E: up to 1 g · F: above 1 g. Closed models are not rated.

The grade is that of the central figure; the grades of the low and high figures are shown when they differ. Bands are fixed, not curved, so a grade means the same thing every month. Formula version energira-rating-1.0.0.

Exports

Grid data sources

SourceStateNeedsPriceTerms
Energy-Charts (Fraunhofer ISE)live—freeCC BY 4.0 unless stated otherwise; /co2eq is undocumented, so used as a cross-check only and not sold
Ember APIwaiting for keya free Ember API key (register at ember-energy.org/data/api), set as EMBER_API_KEYfree (no paid plan listed)CC BY 4.0, personal or commercial use, cite Ember
US EIA Open Data API v2waiting for keya free EIA API key (register at eia.gov/opendata), set as EIA_API_KEYfreeUS Government public domain, cite EIA
Electricity Maps APIblockeda commercial Electricity Maps licence, key set as ELECTRICITYMAPS_KEYfrom EUR 2,500 per year per country (Sustainability plan)free tier is non-commercial; product use needs a paid licence
WattTime API (marginal emissions)blockeda paid WattTime Analyst or Pro plan (MOER data), login set as WATTTIME_USER and WATTTIME_PASSWORDprice on request (not listed)free data is a 0-100 index; research terms forbid commercial use
ENTSO-E Transparency Platformblockeda token (free, requested by email to transparency@entsoe.eu) and written confirmation that commercial re-use is allowed for generation-per-type datafreeopen-data licence covers a listed subset only; commercial re-use not confirmed

Not used: the UK Carbon Intensity API (its terms forbid selling or sublicensing it).

Limits

Sources

Factors energira-factors-2026-11-23 · model energira-model-1.0.0 · rating energira-rating-1.0.0. SPEC and SPECpower are registered trademarks of the Standard Performance Evaluation Corporation.